Overview
The instrument is designed to measure the DC
resistance in inductive and non-inductive circuits
in the range of 1 µΩ -10 kΩ, as well as to generate
Oscillograms of the switching contractor in the high-
speed OLTC.
The device is provided in two versions. The point
of difference between the MIKO-8M and MIKO-
8MA is the built-in battery (MIKO-8MA).
Key Features
MIKO-8M(A) features specialized measurement
modes for different configurations of 10 objects,
taking into account their specific features, while
the user can choose a standard object or create a
custom object. This functionality enables the user
to organize the measurement results, and to
ensure easy workflow with the saved data.
Previous
Next
High level of protection and safety conformity
MIKO-8М(A) has the safety certificate IEC 61010-1. The instrument also meets the requirements of electromagnetic compatibility that are applied to class A instruments according to IEC 61326-1.
Touch screen, remote control and bluetooth data transfer
MIKO-8M(A) is equipped with a color graphic touch screen display of high brightness and an intuitive interface, which facilitates interaction with the device.
AUTO 1ph mode
In the AUTO 1ph mode, a patented automatic measurement method is implemented, which guarantees the highest accuracy of the results in a complex electromagnetic environment.
Variable Instrument Configuration
Depending on the type of object, user can select
special measurement modes. For example, for a
resistive object, user can select one of three
modes: AUTO, SINGLE (similar to MIKO-7M(A) or
PERIOD when the measurement process is started
automatically after a specified time interval.
When diagnosing an inductive object, the modes
are the same as in MIKO-7M(A): MANUAL and
AUTO 1ph.
Previous
Next
Specification
1 μΩ – 10 kΩ
1 μΩ ÷ 10 kΩ
±(0.1%+0.5 μΩ)
0.001 – 10 A
0.1 – 10 A
5 digits
Lithium-ion battery
to 1 000 measurements
USB, Bluetooth
TFT color graphic
touch, 800 x 480 pixels
120 W
60 W
~ 90-253 V, 47-63 Hz
= 127-354 V
270 x 250 x 130 mm
2.7 kg / 4 kg
IP 67 (device cover closed)
IP 40 (device cover open)
from -20°C to +55°C