Product description
Product Features
1. With the functions of measurement, controlling , display by using single clip.
2. With PC interface, improve the office automation level, reduce the labor intensity.
3. With LCD, provide friendly operation interface and rich measurement information.
4. Can auto measure the transformer, auto switch the current, voltage load box.
5. Can inform the users the error information in time.
6. Reaching Standard Class 2
7. The transformation ratio of the standard instrument transformer and calibrated instrument transformer doesn’t have to be equal. We can test directly once the rated primary voltage or current of the calibrated transformer is not bigger than that of the standard transformer. And it’s easy to operate.
2. With PC interface, improve the office automation level, reduce the labor intensity.
3. With LCD, provide friendly operation interface and rich measurement information.
4. Can auto measure the transformer, auto switch the current, voltage load box.
5. Can inform the users the error information in time.
6. Reaching Standard Class 2
7. The transformation ratio of the standard instrument transformer and calibrated instrument transformer doesn’t have to be equal. We can test directly once the rated primary voltage or current of the calibrated transformer is not bigger than that of the standard transformer. And it’s easy to operate.
Product Parameters
System Technical Parameters | |
Input Voltage | AC 400V, 50Hz, Three phase four wire |
Input Current | AC 0-50A |
Rated Capacity | 30kVA |
Test Functions | CT Accuracy Test, CT Demagnetization Function, CT Inter-turn Insulation Test, CT Polarity check |
Test method | Computer controlled automatic test |
CT Demagnetization Function | Provided the open-circuit & closed-circuit demagnetization |
Protection function | Provided overcurrent & overvoltage protection |
CT Rated Primary Current | 5~5000A |
CT Rated Secondary Current | 1A, 5A |
Standard CT accuracy | 0.01S class |
Standards Compliance | IEC61869-1, IEC61869-2 |
Test Bench Parameters |
|
Input Voltage | AC 400V, 50Hz, Three phase four wire |
Input Current | AC 0-50A |
Rated Capacity | 30kVA |
Output Voltage | AC 0-420V |
Output Current | AC 0-75A |
Output Voltage Adjustment | Provided the Coarse adjustment & Fine adjustment automatically |
Voltage Adjustment Model | Controlled by computer & tester automatically |
Maximum number of CT objects | 12 CTs at one time |
Protection function | Provided overcurrent & overvoltage protection |
Embedded equipment | ZC-103A Transformer Tester, ZC-113B CT Burden Computer etc. |
Output Test Result | Display on tester and Word report on computer |
The Bench Structure | Horizontal structure |
Color of the Bench | 7035 Gray |